Features
Supports CAN, serial, K-Line, and LIN communications used within the AD5430 series.
Implemented features
| Communication Type | Channels |
| CAN communication functional part | 4 |
| CAN CCP | 1 |
| Serial | 4 |
| K-Line | 1 |
| LIN | 4 (under development) |
Common specifications
| Item | Specification |
| Size | AD5430 long size IO board; requires one slot |
| Operation conditions | Temperature: 5Degreeto 40Degree Humidity: less than 80% RH (no condensation) |
Serial communication specifications
| Number of channels | 4 |
| Transceiver | Software selectable: RS232C, RS422, or RS485 |
| Controller | LTC1387 |
| Baud rate | 5 to 1M baudEach channel can be set independently |
| Connectors | B2L 3.5/14 (WeidMuller) |
| Load for simulation | 1% or less, 4 transmission channels, 9600 baud |
| Terminal resistance | None |
CAN communication specifications
| Number of output channels | 4 x CAN 2.0B active |
| Transmission ID number | Transmission 128; reception 128 (transmission / reception per channel) |
| Transceiver | High speed CAN TJA1041Optional: single wire CAN AU5790 |
| Controller | Philips SJA 1000 |
| Base clock | 16MHz |
| Multi-frame transfer | ISO 15765-2 (OSEC TP) compatible |
| Baud rate | 5,10,20,33,50,66.66,100,125,250,500,1000 kBaud |
| Time stamp resolution | 8µSec |
| CAN feature | Data frame transmission / reception, error frame transmission / reception,listen-only mode, reception timeout |
| Connectors | B2L 3.5/16 (WeidMuller) |
| CAN period output | 1 to 500 mSec. Up to 16 ID can be set up for each channel |
| Isolation | Bus |
| Terminal resistance | None |
CAN CCP communication specifications
| Channels | 1 (CAN2.0B) |
| Transceiver | High speed CAN TJA1041 |
| Controller | Philips SJA 1000 |
| Baud rate | 5kto1Mbit/s5,10,20,33,50,66.66,100,125,250,500,1000 kBaud |
| Connectors | B2L 3.5/16 (WeidMuller) |
| Terminal resistance | None |
K-Line communication specifications
|
Number of channels |
1 |
|
Transceiver |
MC33990D |
|
Controller |
UART(16550 compatible) |
|
Baud rate |
5Baudto10.4kBaud |
|
Connectors |
B2L 3.5/12 (WeidMuller) |
|
Protocol |
Implemented in the model (example KWP2000 protocol) |
|
Load for simulation |
1% or less, 10.4 k baud transmission |
LIN communication specifications (under development)
|
Number of channels |
4 |
|
Master / slave |
Corresponds to both master and slave |
|
Baud rate |
Maximum 20kbps, 2400bps, 9600bps, 19,200bps |
|
Terminals |
B2L 3.5/12 (WeidMuller) |