To meet the needs of most applications, Vertilon offers its PhotoniQ charge integrating data acquisition (DAQ) systems in seven standard configurations ranging from 2 to 128 input channels. All configurations include PC compatible GUI software, Windows based USB drivers, USB cable, and external system power supply. As an option, a negative high voltage module to bias user-supplied PMTs, SPMs, or APDs can be added to any 32, 64, or 128 channel PhotoniQ model. A second high voltage module can be added to the 64 and 128 channel PhotoniQ models for applications such as PET requiring data collection from multiple sensors. All models of PhotoniQ DAQ systems can be optionally upgraded with a large event buffer memory that can be used in applications requiring high speed continuous data acquisition. Sensor interface boards for supported PMTs, SPMs, and APDs should be order separately. For a comprehensive description of the features, specifications, and options for all PhotoniQ models, download the PhotoniQ User Manual and Selection Guide here. 
User Manual: PhotoniQ Data Acquisition (DAQ) Systems 
Selection Guide: PhotoniQ Data Acquisition (DAQ) Systems 

PhotoniQ IQSP480 32 Channel Data Acquisition System IQSP480 — 32 Channel Data Acquisition (DAQ) System
• 96 dB dynamic range (16 bits)
• 6.0 usec event pair resolution
• 150 KHz maximum trigger rate
• 1450 pC maximum input charge
• 30 fC RMS equivalent input noise charge
Product Sheet: IQSP480 32 Channel Data Acquisition (DAQ) System
User Manual: IQSP480 / IQSP482 / IQSP580 / IQSP582 DAQ Systems
PhotoniQ IQSP482 64 Channel Data Acquisition System IQSP482 — 64 Channel Data Acquisition (DAQ) System
• 96 dB dynamic range (16 bits)
• 7.0 usec event pair resolution
• 120 KHz maximum trigger rate
• 1450 pC maximum input charge
• 30 fC RMS equivalent input noise charge
Product Sheet: IQSP482 64 Channel Data Acquisition (DAQ) System
User Manual: IQSP480 / IQSP482 / IQSP580 / IQSP582 DAQ Systems
PhotoniQ IQSP580 32 Channel Data Acquisition System IQSP580 — 32 Channel High Speed Data Acquisition (DAQ) System
• 84 dB dynamic range (14 bits)
• 2.5 usec event pair resolution
• 390 KHz maximum trigger rate
• 875 pC maximum input charge
• 100 fC RMS equivalent input noise charge
Product Sheet: IQSP580 32 Channel Data Acquisition (DAQ) System
User Manual: IQSP480 / IQSP482 / IQSP580 / IQSP582 DAQ Systems
PhotoniQ IQSP582 64 Channel Data Acquisition System IQSP582 — 64 Channel High Speed Data Acquisition (DAQ) System
• 84 dB dynamic range (14 bits)
• 3.2 usec event pair resolution
• 250 KHz maximum trigger rate
• 875 pC maximum input charge
• 100 fC RMS equivalent input noise charge
Product Sheet: IQSP582 64 Channel Data Acquisition (DAQ) System
User Manual: IQSP480 / IQSP482 / IQSP580 / IQSP582 DAQ Systems
PhotoniQ IQSP584 128 Channel Data Acquisition System IQSP584 — 128 Channel High Speed Data Acquisition (DAQ) System
• 84 dB dynamic range (14 bits)
• 6.5 usec event pair resolution
• 140 KHz maximum trigger rate
• 875 pC maximum input charge
• 100 fC RMS equivalent input noise charge
Product Sheet: IQSP584 128 Channel Data Acquisition (DAQ) System
User Manual: IQSP584 High Speed 128 Channel Data Acquisition (DAQ) System
PhotoniQ IQSP418 Expandable 2 to 8 Channel Data Acquisition System IQSP418 — Field Expandable High Dynamic Range Data Acquisition (DAQ) System
• Field expandable from 2 to 8 channels
• Individual sensor inputs
• 96 dB dynamic range (16 bits)
• 6.0 usec event pair resolution
• 150 KHz maximum trigger rate
• 1450 pC maximum input charge
• 30 fC RMS equivalent input noise charge
Product Sheet: IQSP418 Field Expandable Data Acquisition (DAQ) System
User Manual: IQSP418 / IQSP518 DAQ Systems
PhotoniQ IQSP518 Expandable 2 to 8 Channel Data Acquisition System IQSP518 — Field Expandable High Speed Data Acquisition (DAQ) System
• Field expandable from 2 to 8 channels
• Individual sensor inputs
• 84 dB dynamic range (14 bits)
• 2.5 usec event pair resolution
• 390 KHz maximum trigger rate
• 875 pC maximum input charge
• 100 fC RMS equivalent input noise charge
Product Sheet: IQSP518 Field Expandable Data Acquisition (DAQ) System
User Manual: IQSP418 / IQSP518 DAQ Systems